Products




½ÅÈ£¹ß»ý±â
  ÇÔ¼ö ½ÅÈ£ ¹ß»ý±â
¿ÖÀ² ¸ÞŸ
º¥Ä¡Å¸ÀÔ µðÁöÅÐ ¸ÖƼ¸ÞŸ 
  ¹Ð¸®º¼Æ® ¸ÞŸ




ÀÚ ·á ½Ç


 



¿ÖÀ² ¸ÞŸ

- Auto Range Distortion Measurement
- Auto or Hold Function Selectable
- 7 Distortion Ranges : 0.1 ~ 100 %
- Frequency : 20 Hz ~ 20 kHz Continuously Adjustable in 3 Ranges
- 3 Spot Frequency : 400 Hz, 1 kHz, 10 kHz
- 12 AC Voltage Ranges : 1 mV RMS ~ 300 V RMS

 Distortion Measuring

  Measuring Range
  Fundamental Wave Range
  Input Level
  Fundamental Wave Suppression
  Survival Distortion
  0.1 % 100 % 7 Steps, error ¡Â3 % (full scale)
  20 Hz ~ 20 kHz, 3 frequency point 400 Hz, 1 kHz, 10 kHz
  100 mV RMS ~ 300 V RMS
  ¡µ80 dB
¡´0.03 % (including noise)

  AC Voltage Measuring

  Measuring Range   1 mV RMS ~ 300 V RMS full scale
  Decibel Scale
  - 60 dB ~ + 50 dBm steps with 10 dB
  - 20 dB ~ + 1 dBm (0 dB = 1 V)
  - 20 dB ~ + 3.2 dBm (0 dB = 1 mW 600 ¥Ø)
  Frequency Response

  100 mV ~ 300 V range 20 Hz ~ 200 kHz, ± 0.5 dB
  1 mV ~ 30 mV range 20 Hz ~ 200 kHz, ± 1 dB
  Survival Noise   ¡Â 10 uV (Input end grounded)
  Input Resistance   100 K¥Ø ± 10 %
  Output

  ¡°X¡± axis output : Approx. 1 V RMS full scale of voltage
  ¡°Y¡± axis output : Approx. 500 V RMS full scale of voltage
  Output resistance : approx. 600 ¥Ø
  Max. Input Voltage   ¡´400 (DC + AC Peak)
  Power Supply   220 V / 110 V ± 10 % ; 50 Hz / 60 Hz
  Dimension / Weight   310(W) x 230(H) x 90(L) / 5.5 Kg

 

                                                  

Copyright 2001(c) by AD Power Co., Ltd. . All Rights Reserved

                     °æ±âµµ ºÎõ½Ã ¿ø¹Ì±¸ ¾à´ëµ¿ 193 ºÎõÅ×Å©³ëÆÄÅ© 402-1304È£  TEL : (032)234 - 3791~5  FAX : (032)234 - 3793