A2039
(206×180×116
mm, 2.9 kg)
|
The
A2039 is used for measurement in single-phase
and balanced three-phasse circuits. form
a phase discriminating circuit, the output
of the built-it transducer produces a DC
proportional to the phase between voltage
and current to operate the DC indicator.
|
| A2039
|
| Principle
: Rectifier
Type
Rated Accuracy : 3.0%
Scale :Power Factor : Lead
0-0.3-1.0-0.3-0 Lag
Phase Angle : Lead
90 ¡£-0 ¡£-90 ¡£Lag
Effective Power Factor Measuring Range
:
Lead
0.5-1.0-0.5 Lag
Scale Length : Approx.135mm(5-3/8
¡È)
Freguency Influence :Within ±1.5
¡£Phase angle at 45~65Hz
Model |
code |
Freguency |
Voltage |
2039 |
01 |
0.2/1A |
120V/240V
(USABLE IN THE RANGE
OF 60 TO 300V) |
2039 |
02 |
1/5A |
2039 |
03 |
5/25A |
|
| Notes
: 1. For ranges higher than 2A, use one
External CurrentTransformer
with
203902 & 203903.
2.
For ranges higher than 300V, use External
Potential Transformer. |
|
|
|

|
A2038
(195×175×87
mm, 1.8 kg) |
The
A2038 uses a freqeency-to-DC current transducer
whith drives a high
sensitivity moving coil type indicator it features
accurate Freguency measurements without noticeable
influence of line voltage fluctuation (50 to 300V)
or wave form distortion.
|
| 
|
Principle
: Freguency sensing transducer
Rated Accuracy : ±0.2% of full scale
value on 45 to 65Hz range
±1.0%
of full scale value on 20 to 100Hz range
±0.5%
of full scale value on 100 to 500Hz range
Scale Length : Approx. 135mm(5-3/8")
Model |
code |
Freguency |
Voltage |
2038 |
01 |
45
to 65Hz |
120V/240V |
2038 |
02 |
20
to 100Hz |
2038 |
03 |
100
to 300Hz |
|
| Notes
: For voltages higher than specified, use External
Potential Transformer. |


Single Phase
|
Three Phase
|
|
Current
Range
|
Multiplying
Constant
|
|
Voltage
Range
|
|
120
V
|
240
V
|
|
1
A
|
1
|
2
|
|
5
A
|
5
|
10
|
|
25
A
|
25
|
50
|
|
|
Current
Range
|
Multiplying
Constant
|
|
Voltage
Range
|
|
120
V
|
240
V
|
|
1
A
|
2
|
4
|
|
5
A
|
10
|
20
|
|
25
A
|
50
|
100
|
|
|
|
|
|
|
|
|
Copyriht
2001(c) by AD Power Co., Ltd. All Rights Reserved. TEL:(82)32-234-3791~5 FAX:(82)32-234-3793
(zipcode:420-140) 402/1304 Advanced Instrument Center, #193 Yakdae-Dong, Wonmi District, Buchon City, Kyunggi-DO, Korea
|